HOSE FITTINGS - Eaton

hose fittings to the appropriate requirements established by the SAE. Therefore, the performance ratings of these hose fittings meet the SAE requirements. It is possible to order a hose assely with a fitting terminal end that has a performance rating lower than the hose rating. When ordering hose asselies, please keep the terminal end

Hydraulic Fitting Thread Identifiion Manual U.S.A. 2014

the dimensions found on charts in the following pages. As an example, a fitting will be defined as: Continental ContiTech EP B2-NPMX-0606 with 3/8-18 threads. From the hydraulic alog, the fitting can be identified as a NPTF/ MALE/SWIVEL. The -6 fitting …

Standard Hose Fittings Brochure - Hydraulic Hose

Dimensions and general characteristics may be changed at any time without prior notice. SAE 3000 SAE 6000 flanges SAE long drop Blank Junction Specials Specials BSP 60° loose back nut O''Ring Hose Fittings Hydraulic& OffshoreSupplies Tel: +44 (0)191 549 7335 Fax: +44 (0)191 516 0004 Email: [email protected] Website: /p>

Hydraulic hose - SAE standards | Hydraulics & Pneumatics

Technologies; Hose & Tubing; Hydraulic hose - SAE standards. SAE hydraulic hose standards — SAE 100R1 hose should be used with petroleum- and water-based hydraulic fluids, within a temperature range from140° to 100° C. Type A - Consists of an inner tube of oil-resistant

Technical TECHNICAL - Parker Hannifin

Hose E-4 Hose Products Division Parker Hannifin Corporation Wickliffe, Ohio alog 4400 US Technical A B Fittings C Equipment D Accessories E Technical Hose Dash Size -04 -05 -06 -08 -10 -12 -16 -20 -24 -32 -40 -48

HOSE FITTINGS - Eaton

hose fittings to the appropriate requirements established by the SAE. Therefore, the performance ratings of these hose fittings meet the SAE requirements. It is possible to order a hose assely with a fitting terminal end that has a performance rating lower than the hose rating. When ordering hose asselies, please keep the terminal end

Pipe Fittings and Port Adapters - Parker Hannifin

formance with the design criteria of the Society of Automotive Engineers Standards, SAE J514, J530. Parker Fluid Connector products made from steel and brass, 4300 alog Pipe Fittings and Port Adapters Dimensions and pressures for reference only, subject to change.

Understanding Fuel Line Fittings – Straight Thread (and AN

AN Standards as Applied to Fluid Carrying Fittings. Each AN size also references a standard male and thread size that is used on fittings – such as hose end fittings, adapters, and port fittings. This is known as “AN Thread Size”. AN fittings have Straight Thread, and use O-ring seals.

How to Interpret Hose, Tube & Fittings "Dash Sizes"

Fittings are a little different and slightly more complex. In the part nuer 10343-8-6, for example, -6 is the hose size and -8 is the size of the fitting end connection. Did you notice that for hose part nuers, we talked about inside diameter, and for tube part nuers, …

SAE J2552 push-on hose dimensions specifiion

Jul 20, 2019· The SAE J2552 hose and fitting size is normally designated by the fractional inch indiing the nominal hose inside diameter together with the nominal pipe or straight thread size. The SAE hose dash size is equivalent to the nuer of sixteenth inch increments in the hose inside diameter (1 /2 inch I.D. Hose = 8/1 6 = –8 dash size).

DIN/SAE International Standard Hoses

Meet the International Standards DIN EN853/SAE J517 DIN EN856/ISO 6803. 3 DIB SERIES Can be used in construction machinery,industrial cehicel, various of hrdraulic machinery hose. Main appliion DIB Series-1SN/2SN Fittings HOSE ID SIZE E D G L J …

HYDRAULIC HOSE FITTINGS & ADAPTERS

tests according to standards like SAE, ISO, DIN and JIS. bend radius listed for each hose size and type. Maximum ALFAGOMMA hose and fitting are designed, engineered and tested to be used together in an assely. The use of ALFAGOMMA fittings on other manufactures hose

Hydraulic Hose and Hose Fittings Committee - Profile - SAE

For air appliions the maximum working pressure is at 0.7 MPa. Hose and hose fittings are manufactured within certain dimensions with tolerance ranges in order to provide the proper gripping and sealing. SAE J2552 hose from one manufacturer may not be compatible with SAE J2552 hose fittings supplied by another manufacturer.

J516: Hydraulic Hose Fittings - SAE International

This SAE Standard provides general and dimensional specifiions for the most common hose fittings used in conjunction with hydraulic hoses specified in SAE J517 and utilized in hydraulic systems on mobile and stationary equipment. The general specifiions contained in Sections 1 through 15 are

Hydraulic hose - SAE standards | Hydraulics & Pneumatics

Technologies; Hose & Tubing; Hydraulic hose - SAE standards. SAE hydraulic hose standards — SAE 100R1 hose should be used with petroleum- and water-based hydraulic fluids, within a temperature range from140° to 100° C. Type A - Consists of an inner tube of oil-resistant

Link to Master Table of Contents Standards Link to Section

SAE Standards – Hose Fittings J516 All hose fittings used with hoses listed under SAE J517 standard. SAE Standards – Adapters J512, 010102 0104 45° Flare/Pipe J512, 010103 0204 45° Flare/Pipe J512, 010202 2104 45° Flare/Pipe J512, 010203 2204 45° Flare/Pipe J512, 010101 0404 45° Flare/45° Flare J512, 040105 1404 45° Flare/45° Flare

J516B: Hydraulic Hose Fittings - SAE International

This SAE Standard provides general and dimensional specifiions for the most common hose fittings used in conjunction with hydraulic hoses specified in SAE J517 and utilized in hydraulic systems on mobile and stationary equipment.The general specifiions contained in Sections 1 through 17 are ap

J516A: Hydraulic Hose Fittings - SAE International

Rationale: This revision of SAE J516 is a complete rewrite that divides the standard into sections by hose fitting types. The section nuers will match similar parts of ISO 12151, wherever applicable. In addition, the optional inch hex sizes for all hose fittings were removed from all Tables and moved to Appendix D, and the Finish clause was changed to Corrosion Protection with updated

SAE Straight Thread (ORB) - Discount Hydraulic Hose

SAE Straight Thread O-Ring SAE J1926-1 This fitting is also known as O-Ring Boss (ORB) Recommended by the NFPA for optimal leakage control in medium and high pressure hydraulic systems. The male fitting has a straight thread and O-ring. The port has a straight thread, a machined surface (minimum spotface) and a chamfer to accept the O-ring.

SAE Hydraulic Hose – Ideal for Low, Medium and High

As we all know, the SAE standard is an important standard in hydraulic hose design, construction and pressure rating to ensure that hydraulic hoses meet minimum construction requirements. Here are All completed SAE standard hydraulic hoses ranges from R1 to R17. You can refer to them according to the drawings, section structures and specs.

Link to Master Table of Contents Standards Link to Section

SAE Standards – Hose Fittings J516 All hose fittings used with hoses listed under SAE J517 standard. SAE Standards – Adapters J512, 010102 0104 45° Flare/Pipe J512, 010103 0204 45° Flare/Pipe J512, 010202 2104 45° Flare/Pipe J512, 010203 2204 45° Flare/Pipe J512, 010101 0404 45° Flare/45° Flare J512, 040105 1404 45° Flare/45° Flare

SAE Hydraulic Hose | McMaster-Carr

Made of nylon, this hose is lighter and easier to maneuver than rubber hydraulic hose. The fittings are plated for corrosion resistance. The fitting is also known as a JIC (Joint Industrial Council) fitting. It swivels until tightened for easy installation.

AN 37° Flare vs Industrial 37° Flare Fittings: What''s the

These fittings came to be known, throughout the world, as "JIC" fittings. The JIC wanted the prestige of SAE for the fitting standard. They convinced SAE to take on the task and helped in the development of the standard. Thus, the SAE standard 37° flare fitting became part of SAE J514 in 1950. The fitting became an ISO standard, ISO 8434, in

Hydraulic Flanges and Components - Parker Hannifin

methods of connecting a tube, hose, pipe or another fitting to the SAE standard 4-bolt flange port. Flange Fittings — All Parker flange fittings, except for those with square mounting hole patterns (nomenclature code QS), are designed to conform to O-ring groove, bolt holes and bolt pattern dimensions of either Code 61 or Code 62 of SAE J518

AN / NPT / Metric / INCH (SAE) Conversion Charts

While AN fittings depend on the outside diameter of a tube for sizing, NPT fittings depend on the interior diameter (I.D.) of the fitting itself. The following chart shows the each size''s thread-per-inch count, the I.D. of the fitting, and the AN fitting size with the closest-matching I.D.(inside dimension).