SAFETY FIRST FIRE HOSE TESTING - SOG''s - Page 2 of 2 11. With the air bleeder open, the pressure shall be raised gradually to 45 PSI (± 5 psi) (3.1 bar ± 0.35 bar or 310 kPa ± 35kPa) 12. After the hose test layout is full of water, all the air in each hose line
Fire Hose Type: Double Jacket Hose Inside Dia.: 3" Hose Length: 50 ft. Coupling Material: Aluminum Color: Yellow Thread Type: NST/NH Coupling Lug Style: Rocker Standards: NFPA 1961, 1963 Working Pressure: 400 psi Fire Hose Product Group: Supply Line
Fire Hose Delivered Fast As a distributor of fire hose supplies and equipment since 1976, Rawhide Fire Hose knows you need your order as soon as possible and ships most the same day—free! We work with top domestic and global hose manufacturers to supply you with the hose you need, when you need it.
You have to calculate how many GPM the nozzle is supposed to deliver and at what pressure. Most 1 1/2″ nozzles were 100 GPM at 100 PSI when I was running an engine. Then you have to calculate your friction loss and head pressure and add that to yo
Pressure in a fire hose depends on the type of hose, type of nozzle, and what you’re trying to accomplish with them. An attack line, usually an 1 3/4″ can be used with a solid stream or fog nozzle. A solid stream nozzle requires 50 psi to operate
Supply Lines are 3", 4", 5" and 6". Fire hose is manufactured in different configurations: Single jacket Double jacket Rubber single jacket Hard rubber noncollapsing types Fire Hose Sizes: Each hose is designed for a specific purpose Diameter of fire hose
Fire Hose Type: Double Jacket Hose Inside Dia.: 3" Hose Length: 50 ft. Coupling Material: Aluminum Color: Yellow Thread Type: NST/NH Coupling Lug Style: Rocker Standards: NFPA 1961, 1963 Working Pressure: 400 psi Fire Hose Product Group: Supply Line
WATER SUPPLY AND FIRE STREAM MANAGEMENT M.P. 202.12E 10/10-R Page 1 of 4 PURPOSE To provide guidelines for determining water supply needs and selecting the most effective hose line size or sizes based upon initial and ongoing size-up and
Raptor Hose & Supply
Supply Hose- 3” X Double Jacketed-) 275 psi max. operating pressure X Used to supply an Engine from the hydrant X Used to supply an Engine from another Engine (in-line pumping) X Can supply up to 600 gpm at 150 psi at a distance of 400 ft. X Will require a
NFPA 1961, Standard on Fire Hose. 2. Conduct an acceptance test on each section of fire hose before it is placed in the hose inventory. The test shall comply with the provisions of NFPA 1962, Standard for the Care, Use, and Service Testing of Fire .
2011/5/9· A single supply line can be used by more than one pumper by connecting intake to intake with supply hose. (psi) when pumping into the fire department connection in a high-rise building. 16
With the hose at 45 psi ± 5 psi (3.1 bar ± 0.35 bar or 310 kPa ± 35 kPa), it shall be checked for leakage at each coupling and the couplings tightened with a spanner wrench where necessary.
WATER SUPPLY AND FIRE STREAM MANAGEMENT M.P. 202.12E 10/10-R Page 1 of 4 PURPOSE To provide guidelines for determining water supply needs and selecting the most effective hose line size or sizes based upon initial and ongoing size-up and
This standard defines the design and construction requirements for new fire hose, the testing required to verify the design and construction, and the inspection and testing required of all new fire hose. Please note: This Standard is no longer accepting Public Input due to the Emergency Response and Responder Safety Document Consolidation Plan (consolidation plan) as approved by the NFPA
With a 3" (76.2 mm) inside diameter and a 200 PSI service pressure, this product is suitable as a supply hose for firefighting operations. Choose from two coupling thread options and abrasion-resistant coatings in eight colors (listed below).100'' (30.48 m) of 3" (76.2 mm) Super-Flow Supply Line Fire Hose is lighter and easier to store than 75 foot or 100 foot lengths of hose.
FIRE HOSE FRICTION LOSS T-9 Pressure Loss in PSI per 100'' Hose Equal Length Siamesed Lines.75" 1.0" 1.5" 1.75" 2.0" 2.5" 3.0" 3.5" 4.0" 5.0" 6.0" 2 x 2.5" 3 x 2.5" 2 x 3.0" 10 13.5 3.5 20 50 12.5 30 105 26 40 44 4.531 60 92 10 5 2.5 95 22 11 5 100 25 12
2014/7/1· Using the same 60-psi residual hydrant pressure and five psi for the friction loss in five-inch hose at 1,000 gpm, a department will be able to move 1,000 gpm a total of 1,200 feet, successfully delivering the water in the 600-foot supply line example.
2011/5/9· A single supply line can be used by more than one pumper by connecting intake to intake with supply hose. (psi) when pumping into the fire department connection in a high-rise building. 16
You have to calculate how many GPM the nozzle is supposed to deliver and at what pressure. Most 1 1/2″ nozzles were 100 GPM at 100 PSI when I was running an engine. Then you have to calculate your friction loss and head pressure and add that to yo
2011/5/9· A single supply line can be used by more than one pumper by connecting intake to intake with supply hose. (psi) when pumping into the fire department connection in a high-rise building. 16
Raptor Hose & Supply
This hose is available with 5" storz couplings only. 100'' (30.48 m) of 5" (127 mm) Super-Flow Supply Line Fire Hose is lighter and easier to store than 75 foot or 100 foot lengths of hose. This hose packs flat, lays straight at maximum pressure, and resists contamination from molds, mildew, chemicals, heat and …
Supply fire hose shall be service tested to a minimum of 200 psi. Testing can be done on a fire department’s own fire apparatus. • All non-threaded hose connections shall be provided with locks to ensure against unintentional disconnection.
Heavy-duty municipal supply hose from QRFS is the answer to your supply line needs! Supply hose''s unique design means more fire hose can be packed into the bed of a standard fire truck - up to 200 feet more! Supply hose packs flat and l ays dead straight at full working pressure. dead straight at full working pressure.