psi fire hose specifications

FIREQUIP ATTACK LITE POLY LDH THERMO-POLYURETHANE (TPU) LINED SUPPLY LINE FIRE HOSE SPECIFIIONS

Only the fire department can determine if a proposed product meets and exceeds these specifiions. Scope: This specifiion applies to 4” and 5” sizes of Double Jacket Large Diameter Hose. The hoses shall be suitable for a test pressure of 600 PSI with a.

Standpipes and Hose Systems CHAPTER 3 - National Fire …

(189 L/m) per hose rack at a pressure of 65 psi (4.5 bar). Class III. A coination of Class I and Class II. This type of system is usually equipped with a 21⁄2 in. (65 mm) angle valve for fire department use and a 1 1⁄2 in. (40 mm) hose rack assely for1⁄2

Hose Flow & Sizing

TECHNICAL SPECIFIIONS Air Hose Friction Loss… Approximate pressure loss in psi through 100 foot hose lengths complete with couplings. Cubic feet of air per minute (SCFM) I D. of Gauge 40 50 60 70 80 90 100 110 120 130 140 150 Hose Pressure (psi)

221FR-16 - Fire Resistant Marine Fuel and Engine Hose …

Fire Resistant Marine Fuel and Engine Hose 500 PSI - 221FR Hose | #221FR-16 Parker''s 221FR hose is a transportation hose used for marine fuel and engines that provides fire resistance for …

Fire hose - Wikipedia

Name Definition Attack Attack hose is a fabric-covered, flexible hose used to bring water from the fire pumper to the nozzle. This hose ranges in nominal inside diameter from 1.5 to 3 in (38 to 76 mm) and is designed to operate at pressures up to about 400 psi

SAE vs ISO Specifiion for Hydraulic Hoses

GlobalCore includes 187 (1,000 psi), 387 (3,000 psi), 487 (4,000 psi), 722 (4,000 psi), 787 (5,000 psi), and 797 (6,000) hoses. GlobalCore is a constant working pressure family with color-coded laylines based on pressure rating. Each GlobalCore hose can be

Standpipes and Hose Systems CHAPTER 3 - National Fire …

(189 L/m) per hose rack at a pressure of 65 psi (4.5 bar). Class III. A coination of Class I and Class II. This type of system is usually equipped with a 21⁄2 in. (65 mm) angle valve for fire department use and a 1 1⁄2 in. (40 mm) hose rack assely for1⁄2

Flow Capacities for fire hose - Firehouse Forums - …

2008/5/11· Flow volumes of fire hose Woodie: There is no single flow volume for fire hose. It all depends upon how much pressure you are able to supply in getting the water through the hose line. Then the length of the hose directly affects the amount of pressure it will take.

FIRE HOSE, NOZZLES, BRASS, & HOSE VALVES

38 3 FIRE HOSE, NOZZLES, BRASS, & HOSE VALVES Pre-Folded For Pin Racks For emergency use only, FireTech RACK & REEL FIRE HOSE is fully lined, FM approved, and a great value. It has a proof test pressure of 500 psi, service test of 250 psi, and

Pressure Restricting Hose Valves | American Fire Supply

Pressure restricting hose valves are used to restrict the pressure of flowing water up to 175 PSI. They are angle hose valves with preset orifices which restrict the volume of water and thereby lower the pressure of the flowing water. NFPA requires restricting valves where the inlet pressure exceeds 100 PSI. Pin may be removed by firefighters to allow fully open valve. Unlike pressure

Pressure of a Fire Extinguisher - The Physics Factbook

Fire Extinguisher Maintenance. NIBCO OF COLORADO DIVISION, NIBCO, INC. OSHRC Docket No. 302 Occupational Safety and Health Review Commission, 10 June 1974. "The desired pressure in the cited dry chemical fire extinguisher is 175 psi, such a fire

SAE vs ISO Specifiion for Hydraulic Hoses

GlobalCore includes 187 (1,000 psi), 387 (3,000 psi), 487 (4,000 psi), 722 (4,000 psi), 787 (5,000 psi), and 797 (6,000) hoses. GlobalCore is a constant working pressure family with color-coded laylines based on pressure rating. Each GlobalCore hose can be

FIRE HOSE, NOZZLES, BRASS, & HOSE VALVES

38 3 FIRE HOSE, NOZZLES, BRASS, & HOSE VALVES Pre-Folded For Pin Racks For emergency use only, FireTech RACK & REEL FIRE HOSE is fully lined, FM approved, and a great value. It has a proof test pressure of 500 psi, service test of 250 psi, and

Fire Hose Testing Standard Operating Guidelines

SAFETY FIRST FIRE HOSE TESTING - SOG''s - Page 2 of 2 11. With the air bleeder open, the pressure shall be raised gradually to 45 PSI (± 5 psi) (3.1 bar ± 0.35 bar or 310 kPa ± 35kPa) 12. After the hose test layout is full of water, all the air in each hose line

SINGLE JACKET 500 PSI INDUSTRIAL FIRE HOSE | Marmic …

HYDROSTATIC TESTS: All hose to have an initial test pressure of 500 psi and a service test pressure of 250 psi with a burst of 750 psi. STANDARD STENCILING: Beginning four feet from the end, the hose shall be stenciled in indelible ink with 1" in height and to include - CAMELBACK, month and year of manufacture, and service test to 250 psi.

Booster Hose | Firequip

2011/5/27· Hose Size Working Pressure (psi) Burst Test Pressure (psi) Coupling Bowl Size (in.) Weight per 50’ Uncoupled Weight per 100’ Uncoupled ¾” 800 3200 1’-1/4” 21 lbs 42 lbs 1” 800 3200 1’1/2” 30 lbs 60 lbs 1.25” 300 1200 1-3/4” 125ft = 39.5 lbs 125ft = 98.75 lbs 1.5

Fire Hose Basics - Fire Department families Home Page

NFPA 1963, Standard for Fire Hose Connections – Lists specifiions for fire hose couplings and screw threads. NFPA 1901, Standard for Automotive Fire Apparatus – Requires pumpers to carry: 15 feet of large soft sleeve hose or 20 feet of hard suction hose

Fire hose - Wikipedia

Subsequent to delivery, the hose is tested annually to 400 psi (27.6 bar; 2,760 kPa) by the fire department. While the hose is under pressure, it is inspected for leaks and to determine that the couplings are firmly attached. After testing the hose is drained, dried

Standpipes and Hose Systems CHAPTER 3 - National Fire …

(189 L/m) per hose rack at a pressure of 65 psi (4.5 bar). Class III. A coination of Class I and Class II. This type of system is usually equipped with a 21⁄2 in. (65 mm) angle valve for fire department use and a 1 1⁄2 in. (40 mm) hose rack assely for1⁄2

Booster Hose | Firequip

2011/5/27· Hose Size Working Pressure (psi) Burst Test Pressure (psi) Coupling Bowl Size (in.) Weight per 50’ Uncoupled Weight per 100’ Uncoupled ¾” 800 3200 1’-1/4” 21 lbs 42 lbs 1” 800 3200 1’1/2” 30 lbs 60 lbs 1.25” 300 1200 1-3/4” 125ft = 39.5 lbs 125ft = 98.75 lbs 1.5

Standpipes and Hose Systems CHAPTER 3 - National Fire …

(189 L/m) per hose rack at a pressure of 65 psi (4.5 bar). Class III. A coination of Class I and Class II. This type of system is usually equipped with a 21⁄2 in. (65 mm) angle valve for fire department use and a 1 1⁄2 in. (40 mm) hose rack assely for1⁄2

High Pressure Fire Hose | Products & Suppliers | …

Find High Pressure Fire Hose related suppliers, manufacturers, products and specifiions on GlobalSpec - a trusted source of High Pressure Fire Hose information. Description: can be modified to your department''s need and specifiions. In most cases, a

PVC Fire Extinguisher Booster Hose, Series 167 | Parker NA

PVC Fire Extinguisher Booster Hose is designed for use in portable fire extinguisher units to 150 F and 250 psi, Series 167 Technical Specifiions Maximum Operating Pressure: 250 psi, 1.7 MPa

JGB Hoses - Hoses by Appliion - Extensive line of …

JGB Enterprises stocks hundreds of hoses. If you don''t see the type of hose you are seeking, you may try to loe a specific hose by using our "Find Hose" search box or please call one of our specialists at (315) 451-2770 or contact us by email at

Key Fire Hose, 1.75" x 50'' Red, DJ, ECO, 800 PSI, 1.5"NH | …

Standards: Fire hose manufactured to this specifiion shall meet and exceed all performance requirements of NFPA 1961 and Underwriter s Laboratories standards. Couplings: ECO-10 shall be coupled with 6061-T6 extruded aluminum threaded couplings or forged storz.Special threads or other custom features available upon request.